{"id":14613,"date":"2018-05-16T06:55:23","date_gmt":"2018-05-16T06:55:23","guid":{"rendered":"http:\/\/attekno.com\/?page_id=14613"},"modified":"2024-08-14T21:37:24","modified_gmt":"2024-08-14T14:37:24","slug":"fraction-collector","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/scientific\/fermentor\/fraction-collector\/","title":{"rendered":"Fraction Collector and Sampler OMNICOLL"},"content":{"rendered":"<div class=\"row\">\n<div class=\"col-xs-12 col-sm-12\">\n<h1 class=\"product-title\">Fraction Collector<\/h1>\n<p class=\"perex\">Almost unlimited flexibility \u2013 opens new possibilities in chromatography and multiple stream sampling.<\/p>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"col-md-12\">\n<h1>OMNICOLL Fraction Collector and Sampler<\/h1>\n<ul>\n<li>Collects fractions in\u00a0<strong>any racks or recipients of your choice<\/strong><\/li>\n<li>Collects unlimited number of fractions<\/li>\n<li>The electronics and moving parts are placed above the tubes<br \/>\n\u2013 No damage due to spilling<br \/>\n\u2013 Can be placed in a\u00a0<strong>cold bath or any other thermo-stabilized container<\/strong><\/li>\n<li>Fractionation according to\u00a0<strong>time<\/strong>\u00a0<em>(0.1\u2013999.9 min and 1\u20139999 min)<\/em>\u00a0or\u00a0<strong>volume<\/strong>\u00a0<em>(0.05\u2013500 ml or 0.1 to 30\u00a0l)<\/em><\/li>\n<li><strong>Solvent resistant construction<\/strong><\/li>\n<li><strong>Pause<\/strong>\u00a0<em>(from 0 to 999.9 min and 1 to 9999 min)<\/em>\u00a0or rinsing can be programmed between fractions<\/li>\n<li>Up to 20 fractions simultaneously;\u00a0<strong>multi-channel<\/strong>\u00a0operation (optional)<\/li>\n<\/ul>\n<table width=\"662\">\n<tbody>\n<tr>\n<td width=\"236\"><strong>Description<\/strong><\/td>\n<td width=\"425\"><strong>Specification<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Versatile fraction collector and sampler for <strong>chromatographic techniques and automatic liquid dispensing <\/strong>\uf0b7 <strong>Single channel <\/strong>or simultaneous <strong>multi-channel <\/strong>fraction collection\uf0b7 <strong>Types of recipients: <\/strong>Micro-well plates to large volume bottles \/ beakers \/ vessels \/ flasks<\/p>\n<p>\uf0b7 Drop counter, TTL signal, free flow or pump controlled flow, cold room \/ cooling option<\/p>\n<p>\uf0b7 <strong>Safe &amp; sterile handling: <\/strong>Easily placed inside fume hood \/ laminar hood, clean room<\/p>\n<p>\uf0b7 <strong>Dimension: <\/strong>34 (W) x 30 (H) x 49 (D) cm<\/td>\n<td width=\"425\"><strong>Type:<\/strong>\u00a0LAMBDA OMNICOLL \u2013 microprocessor-controlled programmable fraction collector \u2013 sampler<br \/>\n<strong>Collection mode:<\/strong>\u00a0Linear (line), meander (zigzag) or row collection<br \/>\n<strong>Normal modus:<\/strong><br \/>\n<strong>Time:<\/strong>\u00a00.1 to 999.9 minutes (16.67 hours) in 0.1 min steps or 1 to 9999 minutes (166.7 hours) in 1 min steps<br \/>\n<strong>Volume:<\/strong>\u00a00.01 to 500 ml or 0.6 to 30 litres (external counts using LAMBDA peristaltic pump)<br \/>\n<strong>High modus:<\/strong>\u00a0Same as Normal modus, but with a pause between fractions (from 0.1 to 999.9 minutes or 1 to 9999 minutes)<br \/>\n<strong>Remote control:<\/strong><br \/>\n<strong>Normal modus:<\/strong>\u00a0Collector takes a single fraction after an external voltage pulse of 3-12 V (or 12-30 V with a 3300 ohm resistor)<br \/>\n<strong>High modus:<\/strong>\u00a0Collector takes a 1 to 999 fractions after a single external voltage pulse of 3-12 V (or 12-30 V with a 3300 ohm resistor)<br \/>\n<strong>Capacity:<\/strong>\u00a0Any tube rack or container type with a surface smaller than 45 x 31cm<br \/>\n<strong>Standard racks supplied:<\/strong>\u00a0360 tubes of 12-13 mm diameter; 240 tubes of 16 mm diameter; 160 tubes of 20 mm diameter; 96 tubes of 30 mm diameter; The capacity can be increased many times by coupling several lower fraction collector parts together.<br \/>\n<strong>Non-volatile memory:<\/strong>\u00a0Storage of all settings<br \/>\n<strong>Interface:<\/strong>\u00a0RS-232 (optional)<br \/>\n<strong>Power supply:<\/strong>\u00a095\u2013240 V\/60\u201350 Hz AC plug-in power supply with DC 9V\/12W output; possible field operation on 12 V accumulator<br \/>\n<strong>Dimensions:<\/strong>\u00a034 (W) x 30 (H) x 49 (D) cm<br \/>\n<strong>Weight:<\/strong>\u00a06.5 Kg<br \/>\n<strong>Safety:<\/strong>\u00a0CE, meets IEC 1010\/1 norm for laboratory instruments<br \/>\n<strong>Operation temperature :<\/strong>\u00a00-40 \u00b0C<br \/>\n<strong>Operation humidity:<\/strong>\u00a00-90% RH, not condensing<br \/>\n<strong>Remote control:<\/strong>\u00a00-10 V; (option 0-20 or 4-20 mA)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img fetchpriority=\"high\" decoding=\"async\" title=\"Customization possibilities of OMNICOLL fraction collector and sampler\" src=\"https:\/\/www.lambda-instruments.com\/fileadmin\/user_upload\/Overview_of_customization_possibilities_of_the_OMNICOLL_fraction_collector_and_sampler.png\" alt=\"Customization possibilities of OMNICOLL fraction collector and sampler\" width=\"700\" height=\"394\" data-htmlarea-file-uid=\"1059\" \/><\/p>\n<h3>Types of recipients:<\/h3>\n<p>OMNICOLL fraction collector can handle nearly\u00a0<strong>all kinds of sampling tubes and laboratory sampling racks or recipients<\/strong>\u00a0(drops to liters) available on the market.<\/p>\n<ul>\n<li>Micro titre plates, vials, titer tubes, test tubes, Nalgene lab bottles, larger volume bottles, beakers, flasks, etc. can be used with the fraction collector.<\/li>\n<li><strong>No special sampling tubes or test tube racks are needed<\/strong>\u00a0to collect the fractions.<\/li>\n<\/ul>\n<h3>Single stream or multi-stream collection:<\/h3>\n<ul>\n<li>Single stream<\/li>\n<li>Simultaneous multi-stream fractions of up to 20<\/li>\n<\/ul>\n<p>Example configurations of single channel and multichannel fraction collector could be viewed at\u00a0www.fractioncollector.info\/multi-stream-fraction-collection\/.<\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>OMNICOLL\u00a0single channel collector<\/strong><\/td>\n<td><strong>\u00a0<\/strong><\/td>\n<td><strong>OMNICOLL 4-stream fraction collection<\/strong><\/td>\n<td><strong>\u00a0<\/strong><\/td>\n<td><strong>OMNICOLL 6-channel fraction collector<\/strong><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.lambda-instruments.com\/fraction-collector\/single-channel-fraction-collection\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" title=\"OMNICOLL single channel fraction collection with LAMBDA pump\" src=\"https:\/\/www.lambda-instruments.com\/fileadmin\/user_upload\/Fraction_collector_OMNICOLL_for_liquid_chromatography.jpg\" alt=\"OMNICOLL single channel fraction collection with LAMBDA peristaltic pump\" width=\"176\" height=\"208\" data-htmlarea-file-uid=\"1085\" \/><\/a><\/td>\n<td><\/td>\n<td><a href=\"https:\/\/www.lambda-instruments.com\/fraction-collector\/multi-stream-fraction-collection\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" title=\"OMNICOLL multi-stream for 4 free flowing streams in 50 ml Nalgene plastic tubes\" src=\"https:\/\/www.lambda-instruments.com\/fileadmin\/user_upload\/Omnicoll_operation_manual\/multi-channel-fraction-collection-4-channel_configuration.jpg\" alt=\"OMNICOLL multi-stream for 4 free flowing streams in 50 ml Nalgene plastic tubes for lab\" width=\"220\" height=\"196\" data-htmlarea-file-uid=\"987\" \/><\/a><\/td>\n<td><\/td>\n<td><a href=\"https:\/\/www.lambda-instruments.com\/fraction-collector\/multi-stream-fraction-collection\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" title=\"Customized OMNICOLL 6-channel fraction collection into 96-well plates\" src=\"https:\/\/www.lambda-instruments.com\/fileadmin\/user_upload\/News\/OMNICOLL_fraction_collector-customized-6-channel-96-well-plates.jpg\" alt=\"OMNICOLL 6-channel with third-party multichannel pump on 96-well plates\" width=\"235\" height=\"181\" data-htmlarea-file-uid=\"608\" \/><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Highly flexible control:<\/h3>\n<ul>\n<li>Fraction collection or liquid sampling based on volume \/ time \/ drop count \/ controlled by an external signal.<\/li>\n<li>Easy to program and handle.<\/li>\n<li>Unlimited number of fraction collection<\/li>\n<\/ul>\n<h3>Easy extension of tube capacity by additional supports:<\/h3>\n<p>The tube capacity of the LAMBDA OMNICOLL fraction collector and sampler can easily be increased by adding rack supports. Virtually any number of such capacity extensions can be added.<\/p>\n<table width=\"800\">\n<tbody>\n<tr>\n<td><strong>Extended capacity of 12-channel collector with 250 ml bottles: 2 times\u00a0(= 72 fractions)<\/strong><\/td>\n<td><strong>Extended 30 mm tube rack capacity of single channel fraction collector: 3 times (= 288 fractions)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>\u00a0<a href=\"http:\/\/www.fractioncollector.info\/increased-capacity\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" title=\"OMNICOLL with 2 additional supports to collect 72 fractions in 250 ml bottles\" src=\"https:\/\/www.lambda-instruments.com\/fileadmin\/user_upload\/Omnicoll_fraction_collector-sampler-with-250-ml-bottles.jpg\" alt=\"OMNICOLL 12-channel collector with 2 additional supports to collect 72 fractions in 250 ml bottles\" width=\"317\" height=\"211\" data-htmlarea-file-uid=\"113\" \/><\/a><\/strong><\/td>\n<td><a href=\"http:\/\/www.fractioncollector.info\/increased-capacity\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" title=\"OMNICOLL 3 times extended, for 288 fractions on 30 mm tube racks\" src=\"https:\/\/www.lambda-instruments.com\/fileadmin\/user_upload\/Omnicoll_fraction_collector_with_increased_capactiy.jpg\" alt=\"OMNICOLL single channel fraction collector 3 times extended, for 288 fractions on 30 mm tube racks\" width=\"317\" height=\"211\" data-htmlarea-file-uid=\"116\" \/><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Features of the OMNICOLL fraction collector<\/h2>\n<ul>\n<li>The only fraction collector which can be\u00a0<strong>easily programmed for any rack or recipients<\/strong>\u00a0of your choice<\/li>\n<li>All electronic and mechanical components have been miniaturised and placed in one moving part, which is placed\u00a0above the fractions. Therefore, there is\u00a0<strong>no danger of spilling<\/strong>.<\/li>\n<li>The lower part of the fraction collector can be\u00a0placed into a c<strong>old bath, ice bath or any other thermo-stabilized container<\/strong>.<\/li>\n<li>Modern microprocessor controlled system\u00a0using several optical sensors allows for\u00a0<strong>easy programming of the tube positions<\/strong>.<\/li>\n<li>Fraction\u00a0collection according to\u00a0<strong>time or volume<\/strong><\/li>\n<li>Fraction collection in lines or meander like\u00a0(zigzag)<\/li>\n<li>A\u00a0<strong>pause<\/strong>\u00a0<em>(from 0.1 to 999.9 min and 1 to 9999 min)<\/em>\u00a0can be programmed between fractions. Thus, the OMNICOLL fraction collector can be used for taking\u00a0<em>(single or multiple)<\/em>\u00a0samples, e.g. during fermentation processes, cell cultures and other biological or chemical processes.<\/li>\n<li>The\u00a0<strong>pause function<\/strong>\u00a0can be used also for an\u00a0<strong>automatic start-up<\/strong>\u00a0of the fraction collection.<\/li>\n<li><strong>Washing of the tubing<\/strong>\u00a0<em>(line washing)<\/em>\u00a0between samples is possible, since the number of fractions in a serie can be chosen.<\/li>\n<li><strong>Auto-stop<\/strong>\u00a0function\u00a0switches off the fraction collector and the fractionation after a selected rack or at the end of the range<\/li>\n<li>Pump flow stop function\u00a0<strong>avoids spilling between two consecutive fractions<\/strong>.<\/li>\n<li>Only the liquid transferring tubing is moved\u00a0instead of the tubes, this requires much less energy and allows the fraction collector to be miniaturized. Additionally, the\u00a0tubes are easily accessible from all sides.<\/li>\n<li>The\u00a0lower part of the fraction collector can be used for carrying or storage of fractions. A new plastic fixing mat keeps\u00a0the racks or recipients in position.<\/li>\n<li>Several lower parts can be combined to\u00a0<strong>increase the fraction collecting capacity<\/strong>\u00a0of the fraction collector.<\/li>\n<li><strong>Highest user safety<\/strong>\u00a0has been attained by supplying the OMNICOLL fraction collector with a\u00a0<strong>low voltage plug-in power supply<\/strong>. This allows also an easy\u00a0<strong>field application<\/strong>\u00a0of the fraction collector\u00a0<em>(battery operation possible)<\/em>.<\/li>\n<li><strong>Solid metal construction<\/strong>\u00a0makes the OMNICOLL fraction collector<strong>\u00a0insensitive to solvents.<\/strong><\/li>\n<li>Can be\u00a0<strong>easily disassembled<\/strong>\u00a0and requires only\u00a0little storage space<\/li>\n<li><strong>Low-maintenance<\/strong>\u00a0construction<\/li>\n<li>Competitive price<\/li>\n<li><strong>Remote control<\/strong>\u00a0allows sampling after reception of an\u00a0<strong>external signal<\/strong>\u00a0<em>(such as an alarm)<\/em>. In this way, it is possible to obtain important samples during long processes running even during the absence of a supervisor.<\/li>\n<li><strong>Drop counter<\/strong>, inert valve, RS-232 interface,\u00a0<strong>TTL signal based collection<\/strong>\u00a0and other accessories are available as an option<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Fraction Collector Almost unlimited flexibility \u2013 opens new possibilities in chromatography and multiple stream sampling. OMNICOLL Fraction Collector and Sampler Collects fractions in\u00a0any racks or recipients of your choice Collects unlimited number of fractions The electronics and moving parts are placed above the tubes \u2013 No damage due to spilling \u2013 Can be placed in a\u00a0cold bath or any other thermo-stabilized container Fractionation according to\u00a0time\u00a0(0.1\u2013999.9&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":14529,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-14613","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/14613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=14613"}],"version-history":[{"count":9,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/14613\/revisions"}],"predecessor-version":[{"id":19382,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/14613\/revisions\/19382"}],"up":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/14529"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=14613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}