{"id":14687,"date":"2018-05-21T03:55:01","date_gmt":"2018-05-21T03:55:01","guid":{"rendered":"http:\/\/attekno.com\/?page_id=14687"},"modified":"2018-05-21T03:57:01","modified_gmt":"2018-05-21T03:57:01","slug":"halo-rb-10","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/halo-rb-10\/","title":{"rendered":"Halo RB-10"},"content":{"rendered":"<p>[cmsmasters_row data_shortcode_id=&#8221;00k3hgz6cp&#8221; data_padding_bottom_mobile_v=&#8221;0&#8243; data_padding_top_mobile_v=&#8221;0&#8243; data_padding_bottom_mobile_h=&#8221;0&#8243; data_padding_top_mobile_h=&#8221;0&#8243; data_padding_bottom_tablet=&#8221;0&#8243; data_padding_top_tablet=&#8221;0&#8243; data_padding_bottom_laptop=&#8221;0&#8243; data_padding_top_laptop=&#8221;0&#8243; data_padding_bottom=&#8221;50&#8243; data_padding_top=&#8221;0&#8243; data_bg_parallax_ratio=&#8221;0.5&#8243; data_bg_size=&#8221;cover&#8221; data_bg_attachment=&#8221;scroll&#8221; data_bg_repeat=&#8221;no-repeat&#8221; data_bg_position=&#8221;top center&#8221; data_color=&#8221;default&#8221; data_bot_style=&#8221;default&#8221; data_top_style=&#8221;default&#8221; data_padding_right=&#8221;3&#8243; data_padding_left=&#8221;3&#8243; data_width=&#8221;boxed&#8221;][cmsmasters_column data_width=&#8221;1\/1&#8243; data_shortcode_id=&#8221;n55r1kez4&#8243; data_animation_delay=&#8221;0&#8243; data_border_style=&#8221;default&#8221; data_bg_size=&#8221;cover&#8221; data_bg_attachment=&#8221;scroll&#8221; data_bg_repeat=&#8221;no-repeat&#8221; data_bg_position=&#8221;top center&#8221;][cmsmasters_text shortcode_id=&#8221;5xryb1cwhr&#8221; animation_delay=&#8221;0&#8243;]<\/p>\n<dl>\n<dd class=\"red\"><\/dd>\n<dd><\/dd>\n<\/dl>\n<div class=\"item2Cont\">\n<p>The Halo RB-10 is a ratio beam spectrophotometer with an extensive array of built in functions for versatility and suitability to many analytical and biological applications. The ratio beam optics imparts greater accuracy and reproducibility than the conventional, single beam optics.<\/p>\n<p><img decoding=\"async\" class=\"size-full wp-image-14688 alignleft\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2018\/05\/20125211111221804.jpg\" alt=\"\" width=\"210\" height=\"220\" \/><\/p>\n<p><strong>Spectral Features<br \/>\n<\/strong>Boasting a 2nm spectral bandpass the Halo RB-10 offers superior spectra and peak resolution.<br \/>\nOther specifications include an impressive wavelength accuracy of\u00a0<img decoding=\"async\" src=\"http:\/\/www.dynamica-eu.com\/uploadfile\/20120530094756789.jpg\" border=\"0\" \/>0.5nm, noise level 0.0005Abs (500nm) and stray light\u00a0<img decoding=\"async\" src=\"http:\/\/www.dynamica-eu.com\/uploadfile\/20120530094746967.jpg\" border=\"0\" \/>0.05% (220nm NaI, 340nm NaNO2).<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Built-in and Diverse Range of Measurement Modes<br \/>\nPhotometry Mode:<\/strong>\u00a0Perform quantitative analyses in either absorbance or transmittance modes. Select from single wavelength, up to 6 multiple individual wavelengths, nucleic acid\/protein A260\/A280 ratios and set up calibration curves with up to 20 standards for concentration measurements.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Time Scan:<\/strong>\u00a0Perform kinetic measurements for time periods ranging from 1 minute to &gt;27 hours. Measurement intervals are factory preset and automatically selected when the scan time is set.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Wavelength scan:<\/strong>\u00a0Perform a full spectral scan from 190 to 1,100nm at any of 8 incremental and preset selectable scan speeds starting from a high resolution 10nm\/minute up to a swift 3,600nm \/minute. Data is displayed as either numerical values or a graphical spectrum.\u00a0 Furthermore perform downstream processing of data, such as peak \/ valley search or smoothing, directly on board or with the optional Halo UV Detective software.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dual Lamp Advantage<br \/>\n<\/strong>By virtue of the halogen tungsten and deuterium lamps typically found in higher end, analytical spectrophotometers the Halo RB-10 wavelength range is an impressive 190nm \u00a8C 1,100nm.\u00a0 A dual lamp system also results in higher accuracy than corresponding xenon lamps. Lamp switching is automatic (by default at 340nm) and both lamps are long life.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>User friendly operation and information rich LCD display<br \/>\n<\/strong>The 94mm x 70mm, backlit LCD screen with adjustable brightness control is sufficiently large to display a large array of data even in a graphical format.\u00a0 The seamless and chemical resistant keypad is designed for easy and quick selection of navigation and function features whilst protecting against any laboratory spills.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Validation Functions<br \/>\n<\/strong>To ensure optimum instrument performance, a self-diagnostic function incorporating a number of parameters is executed each time the Halo RB-10 is switched on.\u00a0 The Halo RB-10 is also equipped with a GLP\/GMP feature for analyses requiring validation and auditing. Parameters such as wavelength accuracy, wavelength reproducibility, bandpass, baseline flatness, baseline stability and noise level can be all validated and the audit report printed.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Stand alone or PC Operation<br \/>\n<\/strong>The Halo RB-10 is fully equipped and capable of executing all functions in standalone mode. Simply connect a standard laser printer for direct printouts of data and graphs.\u00a0 For more advanced analyses and reporting, the simple slide of a switch places the Halo RB-10 under the direct control of the optional UV Detective software.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>4-Sample Cuvette Holder<br \/>\n<\/strong>A cuvette holder \/ changer with a 4-cuvette capacity is supplied as standard.\u00a0 Measurement can be expedited by inserting the 4 cuvettes in tandem and manually sliding the holder \/ changer forwards or backwards to select the appropriate cuvette for measurement.<\/p>\n<\/div>\n<p>[\/cmsmasters_text][\/cmsmasters_column][\/cmsmasters_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[cmsmasters_row data_shortcode_id=&#8221;00k3hgz6cp&#8221; data_padding_bottom_mobile_v=&#8221;0&#8243; data_padding_top_mobile_v=&#8221;0&#8243; data_padding_bottom_mobile_h=&#8221;0&#8243; data_padding_top_mobile_h=&#8221;0&#8243; data_padding_bottom_tablet=&#8221;0&#8243; data_padding_top_tablet=&#8221;0&#8243; data_padding_bottom_laptop=&#8221;0&#8243; data_padding_top_laptop=&#8221;0&#8243; data_padding_bottom=&#8221;50&#8243; data_padding_top=&#8221;0&#8243; data_bg_parallax_ratio=&#8221;0.5&#8243; data_bg_size=&#8221;cover&#8221; data_bg_attachment=&#8221;scroll&#8221; data_bg_repeat=&#8221;no-repeat&#8221; data_bg_position=&#8221;top center&#8221; data_color=&#8221;default&#8221; data_bot_style=&#8221;default&#8221; data_top_style=&#8221;default&#8221; data_padding_right=&#8221;3&#8243; data_padding_left=&#8221;3&#8243; data_width=&#8221;boxed&#8221;][cmsmasters_column data_width=&#8221;1\/1&#8243; data_shortcode_id=&#8221;n55r1kez4&#8243; data_animation_delay=&#8221;0&#8243; data_border_style=&#8221;default&#8221; data_bg_size=&#8221;cover&#8221; data_bg_attachment=&#8221;scroll&#8221; data_bg_repeat=&#8221;no-repeat&#8221; data_bg_position=&#8221;top center&#8221;][cmsmasters_text shortcode_id=&#8221;5xryb1cwhr&#8221; animation_delay=&#8221;0&#8243;] The Halo RB-10 is a ratio beam spectrophotometer with an extensive array of built in functions for versatility and suitability to many analytical and biological applications. The ratio beam optics&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-14687","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/14687","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=14687"}],"version-history":[{"count":1,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/14687\/revisions"}],"predecessor-version":[{"id":14690,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/14687\/revisions\/14690"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=14687"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}