{"id":15459,"date":"2020-10-27T22:34:28","date_gmt":"2020-10-27T15:34:28","guid":{"rendered":"http:\/\/attekno.com\/?page_id=15459"},"modified":"2024-07-02T02:21:03","modified_gmt":"2024-07-01T19:21:03","slug":"hot-water-circulator-hc-15","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/hot-water-circulator-hc-15\/","title":{"rendered":"Hot Water Circulator HC-15"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"15459\" class=\"elementor elementor-15459\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-575a63b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"575a63b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0f280fb\" data-id=\"0f280fb\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3768a8a elementor-widget elementor-widget-image\" data-id=\"3768a8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"630\" height=\"576\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2024\/07\/Hot-water-circulator.jpg\" class=\"attachment-large size-large wp-image-19184\" alt=\"Hot water circulator\" srcset=\"https:\/\/attekno.com\/wp-content\/uploads\/2024\/07\/Hot-water-circulator.jpg 630w, https:\/\/attekno.com\/wp-content\/uploads\/2024\/07\/Hot-water-circulator-300x274.jpg 300w\" sizes=\"(max-width: 630px) 100vw, 630px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Hot water circulator<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-38359d7a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"38359d7a\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cd7bbce\" data-id=\"cd7bbce\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2b387f1d elementor-widget elementor-widget-text-editor\" data-id=\"2b387f1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<img decoding=\"async\" class=\"alignnone size-full wp-image-15460\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/Hot-Water-Circulator-HC-15.jpg\" alt=\"\" width=\"211\" height=\"280\" \/>\r\n\r\n&nbsp;\r\n\r\n<strong>Description<\/strong>\r\n<h4>Circulation the hot water up to +80\u2103 with high accuracy \u00b1 0.5\u2103 . Various customized such as heater output and pump capacity upon the request. Heater output: 15.0kW<\/h4>\r\n<h3>Applications<\/h3>\r\n<ul>\r\n \t<li>Hot water circulation to molding machine,Semiconductor manufacturing equipment, HVAC etc.<\/li>\r\n \t<li>A source of heat load for equipment testing.<\/li>\r\n<\/ul>\r\n<h3>Features<\/h3>\r\n<h5><strong>Hot water circulator with high accuracy. Various customized such as heater output\u00a0and number of pumps etc.<\/strong><\/h5>\r\nHeating temperature control with high accuracy \u00b1 0.1\u2103 in temperature range 40\u2103 to 80\u2103 .\u00a0Various customized such as heater output and number of pumps, piping material, etc. based on the following models.\r\nPlease feel free to contact us.\r\n<table width=\"559\">\r\n<tbody>\r\n<tr>\r\n<td width=\"212\">Specifications<\/td>\r\n<td width=\"347\"><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\"><\/td>\r\n<td width=\"347\"><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\"><strong>Model<\/strong><\/td>\r\n<td width=\"347\"><strong>HC-15<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\"><strong>Temperature range<\/strong><\/td>\r\n<td width=\"347\"><strong>+40<\/strong><strong>\u2103<\/strong><strong>\u301c<\/strong><strong>+80<\/strong><strong>\u2103<\/strong><strong>(*1)<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\"><strong>Control accuracy<\/strong><\/td>\r\n<td width=\"347\"><strong>PID controller, \u00b10.5<\/strong><strong>\u2103<\/strong><strong> (*2)<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\"><strong>Heater output<\/strong><\/td>\r\n<td width=\"347\"><strong>15.0kW<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td rowspan=\"3\" width=\"212\">Pump ability\uff0850\/60Hz\uff09<\/td>\r\n<td width=\"347\">Maximum discharge pressure: 0.59MPa<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"347\">Flow rate: 42\/55 L\/min (*3)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"347\">Motor output: 0.75kW<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\">Water bath capacity (at 80% water level)<\/td>\r\n<td width=\"347\">110L<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\">Safety device\/function<\/td>\r\n<td width=\"347\">Short\/Over current breaker, Phase-reversal relay, Warning and Cut off for low water, Circulating water high temperature, Pump over-current, Overheating protection<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\">Connecting pipe diameter (Circulating fluid in\/out)<\/td>\r\n<td width=\"347\">Rc1<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\">External dimensions<\/td>\r\n<td width=\"347\">627\u00d7772\u00d71130Hmm<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\">Weight<\/td>\r\n<td width=\"347\">approx.200kg<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\">Power Supply (three phase AC200V, 50\/60Hz)<\/td>\r\n<td width=\"347\">60A<\/td>\r\n<\/tr>\r\n<tr>\r\n<td width=\"212\">Operation current\uff0850\/60Hz\uff09<\/td>\r\n<td width=\"347\">46A<\/td>\r\n<\/tr>\r\n<tr>\r\n<td colspan=\"2\" width=\"559\">(*1)The lower limit might be changed depending on operating conditions. Cannot be used for applications circulating water return temperature increases.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td colspan=\"2\" width=\"559\">(*2)Capacity when using tap water. The value when the discharge pressure at 0.3MPa.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td colspan=\"2\" width=\"559\">\u25cfThe sensitivity current in ELCB should be set larger than 30 mA.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td colspan=\"2\" width=\"559\">\u25cfThe primary cooling water is required when cooling function added. The cooling capacity depends on the cooling water conditions (Water temperature and Flow rate).<\/td>\r\n<\/tr>\r\n<tr>\r\n<td colspan=\"2\" width=\"559\">\u25cfThe fee for Delivery, Installing, Piping work and Wiring work are quoted separately.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Hot water circulator &nbsp; Description Circulation the hot water up to +80\u2103 with high accuracy \u00b1 0.5\u2103 . Various customized such as heater output and pump capacity upon the request. Heater output: 15.0kW Applications Hot water circulation to molding machine,Semiconductor manufacturing equipment, HVAC etc. A source of heat load for equipment testing. Features Hot water circulator with high accuracy. Various customized such as heater output\u00a0and&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-15459","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15459","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=15459"}],"version-history":[{"count":4,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15459\/revisions"}],"predecessor-version":[{"id":19187,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15459\/revisions\/19187"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=15459"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}