{"id":15534,"date":"2020-10-27T23:49:03","date_gmt":"2020-10-27T16:49:03","guid":{"rendered":"http:\/\/attekno.com\/?page_id=15534"},"modified":"2020-10-27T23:49:03","modified_gmt":"2020-10-27T16:49:03","slug":"refrigerated-benchtop-centrifuge-10r-14-14r-18r","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/refrigerated-benchtop-centrifuge-10r-14-14r-18r\/","title":{"rendered":"Refrigerated Benchtop Centrifuge (10R; 14-14R; 18R)"},"content":{"rendered":"<ul>\n<li><strong>Centrifuge Refrigerated Benchtop Centrifuge 10R<\/strong><br \/>\n<img decoding=\"async\" class=\"alignnone size-medium wp-image-15537\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/10-300x143.jpg\" alt=\"\" width=\"300\" height=\"143\" srcset=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/10-300x143.jpg 300w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/10.jpg 388w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/li>\n<\/ul>\n<p><strong>Description<\/strong><\/p>\n<p>The 3-litre capacity Velocity 10R features powerful refrigeration combined with an exceptional maximum speed of 10,000 RPM offer the versatility and convenience to manage a wide range of larger scale applications.<\/p>\n<p><strong>Powerful Refrigeration<\/strong><\/p>\n<p>A powerful non-CFC compressor cools the chamber quickly whilst maintaining the rotor at set temperature during centrifugation. Twin cooling fans &#8211; one each for the compressor and motor respectively &#8211; dissipate heat quickly to improve cooling efficiency and extend motor life.<\/p>\n<p><strong>Quiet Operation<\/strong><\/p>\n<p>Noise abating insulation in the console including lower noise fans combine to reduce the audible operating noise to 58dB.<\/p>\n<p><strong>Safety Features<\/strong><\/p>\n<ul>\n<li>Non-contact imbalance detection and shutdown based on the run profile for each rotor across its entire speed range rather than the inferior and conventional micro-switch detector.<\/li>\n<li>Dual lid electronic interlock<\/li>\n<\/ul>\n<p>Over speed and motor overheat detection and shutdown.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Specification<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone  wp-image-15538\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v10.png\" alt=\"\" width=\"890\" height=\"497\" srcset=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v10.png 982w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v10-600x335.png 600w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v10-300x168.png 300w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v10-768x429.png 768w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v10-580x324.png 580w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v10-860x481.png 860w\" sizes=\"(max-width: 890px) 100vw, 890px\" \/><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li><strong>Refrigerated Benchtop Centrifuge 14-14R\\<br \/>\n<\/strong><img decoding=\"async\" class=\"alignnone size-full wp-image-15536\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/14.jpg\" alt=\"\" width=\"210\" height=\"210\" srcset=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/14.jpg 210w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/14-100x100.jpg 100w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/14-150x150.jpg 150w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/14-75x75.jpg 75w\" sizes=\"(max-width: 210px) 100vw, 210px\" \/><\/li>\n<\/ul>\n<p><strong>Description<\/strong><\/p>\n<p><strong>Powerful Refrigeration (Velocity 14R)<\/strong><strong><br \/>\n<\/strong>A powerful non-CFC compressor cools the chamber quickly whilst maintaining the rotor at set temperature during centrifugation.\u00a0 Twin cooling fans &#8211; one each for the compressor and motor respectively &#8211; dissipate heat quickly to improve cooling efficiency and extend motor life.<\/p>\n<p><strong>Actual Sample (Rotor) Temperature Measurement and Display (Velocity 14R)<\/strong><strong><br \/>\n<\/strong>The temperature displayed on the LCD panel during centrifugation is that of the rotor (and hence samples) and not the temperature of the chamber nor the temperature at the sensor to allow for more precise, reproducible and efficient experimentation.<\/p>\n<p><strong>Safety Features<\/strong><strong><br \/>\n<\/strong>Non-contact imbalance detection and shutdown based on the run profile for each rotor across its entire speed range rather than the inferior and conventional micro-switch detector.<\/p>\n<p>Guard barrier<br \/>\nDual lid electronic interlock<br \/>\nAuto-hinge for improved sealing and door opening<br \/>\nOver speed detection and shutdown<br \/>\nMotor overheat detection and shutdown<\/p>\n<p><strong>User Friendly Operation and Information Rich Display<\/strong><strong><br \/>\n<\/strong>Parameters are quickly and effortlessly inputted through the uncomplicated touch pad interface and displayed on the brightly backlit and easy to read LCD panel.\u00a0 The LCD panel concurrently displays all experimentation parameters including diagnostic information as it occurs.<\/p>\n<p><strong>Quiet Operation<\/strong><strong><br \/>\n<\/strong>Noise abating insulation in the console including lower noise fans combine to reduce the audible operating noise to\u00a053dB (58 dB for V14R).<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Specification<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15539\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v14.png\" alt=\"\" width=\"922\" height=\"529\" srcset=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v14.png 922w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v14-600x344.png 600w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v14-300x172.png 300w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v14-768x441.png 768w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v14-580x333.png 580w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/v14-860x493.png 860w\" sizes=\"(max-width: 922px) 100vw, 922px\" \/><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<ul>\n<li><strong>Refrigerated Benchtop Centrifuge 18R<br \/>\n<\/strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-15535\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/10\/18R.jpg\" alt=\"\" width=\"210\" height=\"200\" \/><strong><br \/>\n<\/strong><\/li>\n<\/ul>\n<p><strong>Description<\/strong><\/p>\n<p><strong>Powerful Refrigeration <\/strong><\/p>\n<p>A powerful non -cfc compressor cools the chamber quickly whilst maintaining the rotor at set temperature during centrifugation. furthermore, twin cooling fans \u2013 one each for the compressor and motor respectively &#8211; dissipate heat quickly to improve cooling effi ciency and extend motor life.<\/p>\n<p><strong>Actual sample (rotor) temperature Measurement and Display<\/strong><\/p>\n<p>The temperature displayed on the lcD panel during centrifugation is that of the rotor (and hence samples) and not the temperature of the chamber nor the temperature at the sensor to allow for more precise, reproducible and effi cient experimentation.<\/p>\n<p><strong>Safety is Paramount<\/strong><\/p>\n<p>The Velocity 18R offers many safety features in the unlikely event of an emergency such as: non-contact imbalance detection and shutdown based on the run profi le for each rotor across its entire speed range rather than the inferior and conventional micro-switch detector.<\/p>\n<p>&gt; Guard barrier<\/p>\n<p>&gt; Dual lid electronic interlock<\/p>\n<p>&gt; Auto-hinge for improved sealing and door opening<\/p>\n<p>&gt; Over speed detection and shutdown<\/p>\n<p>&gt; Motor overheat detection and shutdown<\/p>\n<p><strong>User friendly operation and information rich display<\/strong><\/p>\n<p>parameters are quickly and effortlessly inputted through the uncomplicated touch pad interface and displayed on the brightly backlit and easy to read lcD panel.<\/p>\n<p>The lcD panel concurrently displays all experimentation parameters including diagnostic information as it occurs. furthermore, once centrifugation has commenced, a real time graphic profi le of the centrifugation status is displayed.<\/p>\n<p><strong>Quiet Operation<\/strong><\/p>\n<p>noise abating insulation in the console including lower noise fans combine to reduce the audible operating noise to \u226458 dB.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Specification<\/strong><\/p>\n<p><strong>Maximum speed<\/strong> 18,000 RpM (fA18A rotor)<\/p>\n<p><strong>Maximum Rcf<\/strong> 28,978 x g (fA18c rotor)<\/p>\n<p><strong>Maximum capacity<\/strong> 1,000 ml (4 x 250 ml)<\/p>\n<p><strong>Drive Mechanism<\/strong> Brushless induction<\/p>\n<p><strong>control<\/strong> Microprocessor based<\/p>\n<p><strong>speed Range<\/strong> 300-18,000 RpM (100 RpM increments)<\/p>\n<p><strong>speed Accuracy<\/strong> \u00b120 RpM<\/p>\n<p><strong>speed \/ Rcf conversion<\/strong> yes<\/p>\n<p><strong>Timer <\/strong>1 min &#8211; 99 hrs 59 mins plus holD function<\/p>\n<p><strong>Display<\/strong> Backlit lcD<\/p>\n<p><strong>operating noise<\/strong> &lt;58dB (A)<\/p>\n<p><strong>Temperature Range<\/strong> -20\u00b0c to +40\u00b0c<\/p>\n<p><strong>Temperature Accuracy<\/strong> \u00b12\u00b0c<\/p>\n<p><strong>Memory<\/strong> 9 programs<\/p>\n<p><strong>Acceleration\/Deceleration<\/strong> 9 stages \/ 10 stages<\/p>\n<p><strong>Automatic Rotor identifi cation<\/strong> yes<\/p>\n<p><strong>imbalance Detection<\/strong> yes<\/p>\n<p><strong>Dimensions<\/strong> (l x D x h) 730 x 610 x 380 mm<\/p>\n<p><strong>Weight (net)<\/strong> 100 Kg<\/p>\n<p><strong>power supply<\/strong> single phase Ac220V, 50hz, 10A Ac220V, 60hz Ac110V, 60hz<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Centrifuge Refrigerated Benchtop Centrifuge 10R Description The 3-litre capacity Velocity 10R features powerful refrigeration combined with an exceptional maximum speed of 10,000 RPM offer the versatility and convenience to manage a wide range of larger scale applications. Powerful Refrigeration A powerful non-CFC compressor cools the chamber quickly whilst maintaining the rotor at set temperature during centrifugation. Twin cooling fans &#8211; one each for the compressor&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-15534","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15534","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=15534"}],"version-history":[{"count":2,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15534\/revisions"}],"predecessor-version":[{"id":16214,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15534\/revisions\/16214"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=15534"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}