{"id":15684,"date":"2020-11-17T17:53:57","date_gmt":"2020-11-17T10:53:57","guid":{"rendered":"http:\/\/attekno.com\/?page_id=15684"},"modified":"2024-10-21T16:52:53","modified_gmt":"2024-10-21T09:52:53","slug":"biosafety-cabinet-class-ii-a2","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/biosafety-cabinet-class-ii-a2\/","title":{"rendered":"Biosafety Cabinet Class II A2"},"content":{"rendered":"<figure id=\"attachment_15685\" aria-describedby=\"caption-attachment-15685\" style=\"width: 258px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-15685 size-full\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/Biosafety-Cabinet-ii2a.jpg\" alt=\"Biosafety Cabinet\" width=\"258\" height=\"296\" \/><figcaption id=\"caption-attachment-15685\" class=\"wp-caption-text\">Biosafety Cabinet<\/figcaption><\/figure>\n<p><strong>Description<\/strong><\/p>\n<p>Three protection: operator, sample and environment.\u00a0Airflow system: 70% air recirculation, 30% air exhaust A2 Cabinet is suitable for working\u00a0with microbiological research in the absence of volatile or toxic chemicals and radionuclide.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Specification<\/strong><\/p>\n<table width=\"747\">\n<tbody>\n<tr>\n<td width=\"94\">Model<\/td>\n<td width=\"137\">BSC-1100IIA2-X<\/td>\n<td width=\"137\">BSC-1300IIA2-X<\/td>\n<td width=\"121\">BSC-1500IIA2-X<\/td>\n<td width=\"137\">BSC-1800IIA2-X<\/td>\n<td width=\"121\">BSC-2000IIA2-X<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Internal Size<\/td>\n<td rowspan=\"2\" width=\"137\">940*\u00a0600*660\u00a0mm<\/td>\n<td rowspan=\"2\" width=\"137\">1150*600*660 mm<\/td>\n<td width=\"121\">1350*600*660<\/td>\n<td width=\"137\">1700*600*660<\/td>\n<td width=\"121\">1800*600*660<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">(W*D*H)<\/td>\n<td width=\"121\">Mm<\/td>\n<td width=\"137\">mm<\/td>\n<td width=\"121\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">External Size<\/td>\n<td rowspan=\"2\" width=\"137\">1100*750*2250mm<\/td>\n<td rowspan=\"2\" width=\"137\">1300*750*2250mm<\/td>\n<td width=\"121\">1500*750*2250<\/td>\n<td rowspan=\"2\" width=\"137\">1873*775*2290mm<\/td>\n<td width=\"121\">1950*800*2170<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">(W*D*H)<\/td>\n<td width=\"121\">Mm<\/td>\n<td width=\"121\">mm<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Tested Opening<\/td>\n<td colspan=\"5\" width=\"653\">Safety Height =\u00a0200 mm(8&#8221;)<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Max Opening<\/td>\n<td width=\"137\">420mm(17\u2019\u2019)<\/td>\n<td width=\"137\">420mm(17\u2019\u2019)<\/td>\n<td width=\"121\">500mm(20\u2019\u2019)<\/td>\n<td width=\"137\">550mm(22\u2019\u2019)<\/td>\n<td width=\"121\">400mm(16\u2019\u2019)<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Inflow Velocity<\/td>\n<td colspan=\"5\" width=\"653\">0.53\u00b10.025 m\/s<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Downflow Velocity<\/td>\n<td colspan=\"5\" width=\"653\">0.33\u00b10.025 m\/s<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">HEPA Filter<\/td>\n<td colspan=\"5\" width=\"653\">Two, 99.999% efficient at 0.3 um.\u00a0Filter life indicator.<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Front Window<\/td>\n<td colspan=\"5\" width=\"653\">Motorized. Two-layer laminated toughened glass\u00a0\u2265 5mm. Anti UV.<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Noise<\/td>\n<td colspan=\"5\" width=\"653\">EN12469 \u2264\u00a058 dB \/ NSF49 \u2264\u00a061\u00a0dB<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"94\">UV Lamp<\/td>\n<td width=\"137\">30W*1<\/td>\n<td width=\"137\">30W* 1<\/td>\n<td width=\"121\">40W* 1<\/td>\n<td width=\"137\">40W*1<\/td>\n<td width=\"121\">40W* 1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"653\">UV timer, UV life indicator, emission of 253.7 nanometers<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"653\">for most efficient decontamination.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"94\">Illuminating Lamp<\/td>\n<td colspan=\"5\" width=\"653\">LED Lamp<\/td>\n<\/tr>\n<tr>\n<td width=\"137\">12W*2<\/td>\n<td width=\"137\">12W*2<\/td>\n<td width=\"121\">16W*2<\/td>\n<td width=\"137\">16W*2<\/td>\n<td width=\"121\">16W*2<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Illumination<\/td>\n<td colspan=\"5\" width=\"653\">\u22651000Lux<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Consumption<\/td>\n<td width=\"137\">760W<\/td>\n<td width=\"137\">800W<\/td>\n<td width=\"121\">900W<\/td>\n<td width=\"137\">900W<\/td>\n<td width=\"121\">1500W<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Waterproof Sockets<\/td>\n<td colspan=\"5\" width=\"653\">Two, total load of two sockets: 500W<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Display<\/td>\n<td colspan=\"5\" width=\"653\">LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Control System<\/td>\n<td colspan=\"5\" width=\"653\">Microprocessor<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Airflow System<\/td>\n<td colspan=\"5\" width=\"653\">70% air recirculation, 30% air exhaust<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Visual and audio alarm<\/td>\n<td colspan=\"5\" width=\"653\">Filter replacement, front window at unsafe height, abnormal airflow velocity.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"94\">Material<\/td>\n<td colspan=\"5\" width=\"653\">Work Zone: 304 stainless steel<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"653\">Main Body: Cold-rolled steel with anti-bacteria powder coating.<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Work Surface Height<\/td>\n<td colspan=\"5\" width=\"653\">750mm<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Caster<\/td>\n<td colspan=\"5\" width=\"653\">Footmaster caster<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Power Supply<\/td>\n<td colspan=\"5\" width=\"653\">AC220V\u00b110%, 50\/60Hz; 110V\u00b110%, 60Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Standard Accessory<\/td>\n<td colspan=\"5\" width=\"653\">LED lamp, UV lamp*2, Base stand, Remote control, Foot switch,\u00a0Drain valve, Waterproof sockets*2<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Optional Accessory<\/td>\n<td colspan=\"5\" width=\"653\">Water and gas tap, Electric height adjustable base stand.<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Gross Weight<\/td>\n<td width=\"137\">243kg<\/td>\n<td width=\"137\">280kg<\/td>\n<td width=\"121\">316kg<\/td>\n<td width=\"137\">395kg<\/td>\n<td width=\"121\">420kg<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">Package Size<\/td>\n<td rowspan=\"2\" width=\"137\">1220\u00d7 1000\u00d7 1840 mm<\/td>\n<td rowspan=\"2\" width=\"137\">1460*1050*1800 mm<\/td>\n<td rowspan=\"2\" width=\"121\">1630*1000*1820 mm<\/td>\n<td rowspan=\"2\" width=\"137\">2000*950*1820 mm<\/td>\n<td rowspan=\"2\" width=\"121\">2090*1050*1860 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"94\">(W*D*H)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Description Three protection: operator, sample and environment.\u00a0Airflow system: 70% air recirculation, 30% air exhaust A2 Cabinet is suitable for working\u00a0with microbiological research in the absence of volatile or toxic chemicals and radionuclide. \u00a0 Specification Model BSC-1100IIA2-X BSC-1300IIA2-X BSC-1500IIA2-X BSC-1800IIA2-X BSC-2000IIA2-X Internal Size 940*\u00a0600*660\u00a0mm 1150*600*660 mm 1350*600*660 1700*600*660 1800*600*660 (W*D*H) Mm mm mm External Size 1100*750*2250mm 1300*750*2250mm 1500*750*2250 1873*775*2290mm 1950*800*2170 (W*D*H) Mm mm Tested Opening Safety&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-15684","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15684","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=15684"}],"version-history":[{"count":2,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15684\/revisions"}],"predecessor-version":[{"id":19453,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15684\/revisions\/19453"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=15684"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}