{"id":15688,"date":"2020-11-17T17:55:19","date_gmt":"2020-11-17T10:55:19","guid":{"rendered":"http:\/\/attekno.com\/?page_id=15688"},"modified":"2020-11-25T08:27:37","modified_gmt":"2020-11-25T01:27:37","slug":"biosafety-cabinet-class-ii-b2","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/biosafety-cabinet-class-ii-b2\/","title":{"rendered":"Biosafety Cabinet  Class II B2"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-15689\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/iib2.jpg\" alt=\"\" width=\"282\" height=\"324\" srcset=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/iib2.jpg 282w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/iib2-261x300.jpg 261w\" sizes=\"(max-width: 282px) 100vw, 282px\" \/><\/p>\n<p><strong>Description<\/strong><\/p>\n<p>Three protection: operator, sample and environment. Airflow system: 0 % air recirculation, 100% air exhaust A Class II B2 BSC, also called a total exhaust cabinet, is necessary when significant amounts of radionuclides and volatile chemicals are expected to be used.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Specification<\/strong><\/p>\n<table width=\"689\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"141\">Model<\/td>\n<td width=\"137\">BSC-1100IIB2-X<\/td>\n<td width=\"137\">BSC-1300IIB2-X<\/td>\n<td width=\"137\">BSC-1500IIB2-X<\/td>\n<td width=\"137\">BSC-1800IIB2-X<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Internal Size<\/td>\n<td rowspan=\"2\" width=\"137\">940*600*660&nbsp;mm<\/td>\n<td rowspan=\"2\" width=\"137\">1150*600*660 mm<\/td>\n<td rowspan=\"2\" width=\"137\">1350*600*660mm<\/td>\n<td rowspan=\"2\" width=\"137\">1700*600*660 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">(W*D*H)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">External Size<\/td>\n<td rowspan=\"2\" width=\"137\">1100*750*2250mm<\/td>\n<td rowspan=\"2\" width=\"137\">1300*750*2250mm<\/td>\n<td rowspan=\"2\" width=\"137\">1500*760*2250mm<\/td>\n<td rowspan=\"2\" width=\"137\">1873*775*2270mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">(W*D*H)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Tested Opening<\/td>\n<td colspan=\"4\" width=\"548\">Safety Height 200 mm\uff088\u2019\u2019\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Max Opening<\/td>\n<td width=\"137\">420mm(17\u2019\u2019)<\/td>\n<td width=\"137\">420mm(17\u2019\u2019)<\/td>\n<td width=\"137\">500mm(20\u2019\u2019)<\/td>\n<td width=\"137\">480mm(20\u2019\u2019)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Inflow Velocity<\/td>\n<td colspan=\"4\" width=\"548\">0.53\u00b10.025 m\/s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Down flow Velocity<\/td>\n<td colspan=\"4\" width=\"548\">0.33\u00b10.025 m\/s<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Pre-Filter<\/td>\n<td colspan=\"4\" width=\"548\">Washable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">HEPA Filter<\/td>\n<td colspan=\"4\" width=\"548\">Two, 99.999% efficiency&nbsp;at 0.3 \u03bcm,filter life indicator.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Front Window<\/td>\n<td colspan=\"4\" width=\"548\">Motorized,two-layer laminated toughened glass&nbsp;\u2265 5mm,anti UV.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Noise<\/td>\n<td colspan=\"4\" width=\"548\">NSF49 \u2264&nbsp;61&nbsp;dB&nbsp;\/&nbsp;EN1246949 \u2264&nbsp;58 dB<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"3\" width=\"141\">UV Lamp<\/td>\n<td width=\"137\">30W*1<\/td>\n<td width=\"137\">30W* 1<\/td>\n<td width=\"137\">40W* 1<\/td>\n<td width=\"137\">40W*1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"548\">UV timer, UV life indicator, emission of 253.7 nanometers<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"548\">for most efficient decontamination.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" width=\"141\">Illuminating Lamp<\/td>\n<td width=\"137\">LED Lamp<\/td>\n<td width=\"137\">LED Lamp<\/td>\n<td width=\"137\">LED Lamp<\/td>\n<td width=\"137\">LED Lamp<\/td>\n<\/tr>\n<tr>\n<td width=\"137\">12W*2<\/td>\n<td width=\"137\">14W*2<\/td>\n<td width=\"137\">16W*2<\/td>\n<td width=\"137\">16W*2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Illumination<\/td>\n<td colspan=\"4\" width=\"548\">\u22651000Lux<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Consumption<\/td>\n<td width=\"137\">700W<\/td>\n<td width=\"137\">850W<\/td>\n<td width=\"137\">900W<\/td>\n<td width=\"137\">1200W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Waterproof Sockets<\/td>\n<td colspan=\"4\" width=\"548\">Two, total load of two sockets: 500W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" width=\"141\">Display<\/td>\n<td colspan=\"4\" width=\"548\">LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time,<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"548\">inflow and downflow velocity, filter life, humidity and temperature, system working time etc.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Control System<\/td>\n<td colspan=\"4\" width=\"548\">Microprocessor<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Airflow System<\/td>\n<td colspan=\"4\" width=\"548\">0% air recirculation, 100% air exhaust<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Alarm<\/td>\n<td colspan=\"4\" width=\"548\">Abnormal airflow velocity; Filter replacement; Front window at unsafe height.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Exhaust&nbsp;Duct<\/td>\n<td colspan=\"4\" width=\"548\">4&nbsp;meters&nbsp;PVC&nbsp;duct,&nbsp;Diameter:300mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" width=\"141\">Material<\/td>\n<td colspan=\"4\" width=\"548\">Work Zone: 304 stainless steel<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"548\">Main Body: Cold-rolled steel with anti-bacteria powder coating.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Work Surface Height<\/td>\n<td colspan=\"4\" width=\"548\">750mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Caster<\/td>\n<td colspan=\"4\" width=\"548\">Foot master caster<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Power Supply<\/td>\n<td colspan=\"4\" width=\"548\">AC 220V\u00b110%, 50\/60Hz; 110V\u00b110%, 60Hz (110V\/60Hz is not applicable to BSC-1800IIB2-X)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" width=\"141\">Standard Accessory<\/td>\n<td colspan=\"4\" width=\"548\">Illuminating lamp,&nbsp;UV&nbsp;lamp*2,base&nbsp;stand,&nbsp;remote&nbsp;control,&nbsp;foot&nbsp;switch,&nbsp;exhaust&nbsp;blower,<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"548\">exhaust&nbsp;duct, drain&nbsp;valve,&nbsp;waterproof&nbsp;sockets*2,&nbsp;pipe&nbsp;strap*2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Optional Accessory<\/td>\n<td colspan=\"4\" width=\"548\">Water&nbsp;and&nbsp;gas&nbsp;tap, Electric height adjustable base stand<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"141\">Gross Weight<\/td>\n<td width=\"137\">246kg<\/td>\n<td width=\"137\">276kg<\/td>\n<td width=\"137\">302kg<\/td>\n<td width=\"137\">408kg<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"64\">Package<\/td>\n<td width=\"77\">Main&nbsp;Body<\/td>\n<td width=\"137\">1230* 990* 1810 mm<\/td>\n<td width=\"137\">1460*1050*1800 mm<\/td>\n<td width=\"137\">1650*990*1810 mm<\/td>\n<td width=\"137\">2000*950*1820 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"77\">Exhaust Blower (W*D*H)<\/td>\n<td width=\"137\">970* 810* 630 mm<\/td>\n<td width=\"137\">970* 810* 630 mm<\/td>\n<td width=\"137\">970* 810* 630 mm<\/td>\n<td width=\"137\">970* 8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Description Three protection: operator, sample and environment. Airflow system: 0 % air recirculation, 100% air exhaust A Class II B2 BSC, also called a total exhaust cabinet, is necessary when significant amounts of radionuclides and volatile chemicals are expected to be used. &nbsp; Specification Model BSC-1100IIB2-X BSC-1300IIB2-X BSC-1500IIB2-X BSC-1800IIB2-X Internal Size 940*600*660&nbsp;mm 1150*600*660 mm 1350*600*660mm 1700*600*660 mm (W*D*H) External Size 1100*750*2250mm 1300*750*2250mm 1500*760*2250mm 1873*775*2270mm (W*D*H)&hellip; <\/p>\n","protected":false},"author":1,"featured_media":16066,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-15688","page","type-page","status-publish","has-post-thumbnail","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15688","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=15688"}],"version-history":[{"count":2,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15688\/revisions"}],"predecessor-version":[{"id":16067,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15688\/revisions\/16067"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media\/16066"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=15688"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}