{"id":15761,"date":"2020-11-18T22:28:43","date_gmt":"2020-11-18T15:28:43","guid":{"rendered":"http:\/\/attekno.com\/?page_id=15761"},"modified":"2026-04-21T17:20:20","modified_gmt":"2026-04-21T10:20:20","slug":"climatic-chamber","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/climatic-chamber\/","title":{"rendered":"Climatic Chamber"},"content":{"rendered":"<p><strong>General Description<\/strong><\/p>\n<p>Moisture is a variable parameter, whose influence is important in a number of physical, chemical or biological processes. The FROILABO environmental chambers can perform almost all temperature and humidity testing processes: drying, aging acceleration, stability testing, electrical testing&#8230; To validate the performance of these operating principles and validate the chambers after manufacture, FROILABO has developed powerful metrology tools. These are connected to national standards, is similar to that used by accredited testing laboratories which allow for the characterization of our chambers according to the principles defined by the Aerospace Industry (Standard Aero 681 RE 01). The Meditest environmental chambers can meet the specific requirements of stability tests in the pharmaceutical industry (ICH standard) but also to test conditioning and aging. This generation of environmental chambers has many advantages in terms of performance and standard equipment. The Meditest FROILABO comply with AFNOR NFX 15-140.<\/p>\n<p><strong>Description<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"362\"><strong>Cilamatic Chamber SP (Humidity Range)<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-15762\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/spcliPicture1.png\" alt=\"\" width=\"126\" height=\"176\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/td>\n<td width=\"362\"><strong>Climatic Chamber Meditest Range<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-15763\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/mrPicture1.png\" alt=\"\" width=\"102\" height=\"197\" \/><\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"362\"><strong>RANGE HOT \/ COLD \/ HUMIDITY <\/strong><\/p>\n<p>\u2022\u00a0 Control range: 0 \u00b0 C to + 60 \u00b0 C<\/p>\n<p>\u2022 Modular Relative Humidity 5% 95%<\/p>\n<p>\u2022 Demineralized water supply 10 litre tank<\/p>\n<p>\u2022 Refrigeration consists of a group of hermetic refrigeration, an air or water condenser depending on the model type and refrigerant HFCR134A (CFC)<\/p>\n<p>\u2022 PT sensor 100 ohms comply with IEC 751 Class A \u2022Capacitive sensor for humidity, allowing direct measurement of relative humidity in the enclo- sure<\/p>\n<p>\u2022 Steam generation by ultrasonic system<\/p>\n<p>\u2022 Double PID controller with digital display and real-set temperature to 1 \/ 10th of a degree<\/p>\n<p>\u2022 Supplied with 2 shelves supporting 20kg each<\/p>\n<p>\u2022 Cable entry 35mm on the right side of the unit<\/p>\n<p>\u2022 Vertical forced convection (provided by 1,2 or 4 tangential fans 450 m3 \/ hour depending on model)<\/p>\n<p>\u2022 The chamber is made of stainless steel (standard Z2CN1809), seamlessly welded to ensure a perfect watertight enclosure for water and vapour<\/p>\n<p>\u2022 Double silicone gasket ensures perfect thermal insulation between the door and the room<\/p>\n<p>\u2022 Outer shell galvanized steel and epoxy paint<\/p>\n<p>\u2022 Insulation glass wool (60mm thick)<\/p>\n<p>\u2022 Mounted on wheels, 2 lockable<\/p>\n<p>\u2022 Sub-tight? interior glass door<\/p>\n<p>\u2022Warranty 24 months<\/p>\n<p>&nbsp;<\/p>\n<p>SP OPTIONS \u2022A power supply system in deionized water or by automatic cartridge \u2022 50mm cable duct (instead of 35mm) \u2022 Power supply 380 V three-phase + with or without neutral \/ 50Hz for SP1000 \u2022 RS485 port for connection of temperature controllers and humidity to a PC and save and manage data remotely \u2022 4 or 16 segments Programming for complex climatic variations \u2022 Electronic Recorder 1 or 2 channels \u2022Keylock \u2022Dry contact for external alarm \u2022 Lighting Point \u2022Additional shelves reinforced or not, max load 40kg \u2022Characterization of the enclosure by an official body \u2022 Inspection window in the door<\/td>\n<td width=\"362\"><strong>MEDITEST RANGE <\/strong><\/p>\n<p>\u2022 Temperature range: 0 \u00b0 C to + 60 \u00b0 C<\/p>\n<p>\u2022 Relative Humidity range of regulated: 25% to 90% RH <strong>GENERAL FEATURES<\/strong><\/p>\n<p>\u2022 2 PID controllers with dual display and a dual high and low temperature alarm integrated<\/p>\n<p>\u2022Ultrasonic humidity generator provides a rapid recovery to preset moisture levels during door opening<\/p>\n<p>\u2022Keylock<\/p>\n<p>\u2022 Safety thermostat 3.1 for sample protection \u2022 Optimized air circulation guarantees excellent chamber temperature uniformity and stability<\/p>\n<p>\u2022 Stainless steel interior for easy cleaning and decontamination operation<\/p>\n<p>\u2022 4 shelves as standard<\/p>\n<p>\u2022 4 wheels, 2 with brakes facilitating the movement of the enclosure (6 and 3 for 1300)<\/p>\n<p>\u2022Cable outlet diam. 35mm on the right side<\/p>\n<p>\u2022Visual alarm water level<\/p>\n<p>\u2022Visual alarm temperature fault<\/p>\n<p>\u2022Automatic feed to connect to the water supply demineralized<\/p>\n<p>\u2022Warranty 24 months<\/p>\n<p>&nbsp;<\/p>\n<p><strong>MEDITEST OPTIONS <\/strong><\/p>\n<p>\u2022Audible alarm of water shortage<\/p>\n<p>\u2022Audible alarm temperature fault, alarm report<\/p>\n<p>\u2022Audible alarm humidity default<\/p>\n<p>\u2022 Exterior door two leaves<\/p>\n<p>\u2022 Electrical socket in the enclosure<\/p>\n<p>\u2022 Scheduler 16 segments<\/p>\n<p>\u2022Additional temperature sensor for traceability \u2022Additional humidity sensor for traceability<\/p>\n<p>\u2022 Electronic temperature recorder mounted two-way front<\/p>\n<p>\u2022Deionized water supply system by manual 10 litre reser- voir<\/p>\n<p>\u2022Automatic feeding system with demineralised water by disposable bottles with resin filter<\/p>\n<p>\u2022 Material characterization by a notified body in accor- dance with standard AFNOR NFX 15-140<\/p>\n<p>\u2022Additional stainless shelves<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>General Specification<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone  wp-image-15764\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/folPicture1.png\" alt=\"\" width=\"570\" height=\"443\" srcset=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/folPicture1.png 341w, https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/folPicture1-300x233.png 300w\" sizes=\"(max-width: 570px) 100vw, 570px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>General Description Moisture is a variable parameter, whose influence is important in a number of physical, chemical or biological processes. The FROILABO environmental chambers can perform almost all temperature and humidity testing processes: drying, aging acceleration, stability testing, electrical testing&#8230; To validate the performance of these operating principles and validate the chambers after manufacture, FROILABO has developed powerful metrology tools. These are connected to national&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-15761","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15761","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=15761"}],"version-history":[{"count":1,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15761\/revisions"}],"predecessor-version":[{"id":15766,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/15761\/revisions\/15766"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=15761"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}