{"id":16082,"date":"2020-11-26T10:12:42","date_gmt":"2020-11-26T03:12:42","guid":{"rendered":"http:\/\/attekno.com\/?page_id=16082"},"modified":"2020-11-26T10:12:44","modified_gmt":"2020-11-26T03:12:44","slug":"karl-fischer-volumetric-titractor-aqv-300","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/karl-fischer-volumetric-titractor-aqv-300\/","title":{"rendered":"Karl Fischer Volumetric Titractor AQV 300"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"155\" height=\"110\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/11\/image-2.png\" alt=\"\" class=\"wp-image-16083\"\/><\/figure>\n\n\n\n<p><strong>DESCRIPTION<\/strong><\/p>\n\n\n\n<p><strong>Features<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Small footprint with integrated magnetic stirrer.<\/li><li>Function guide display allows simple operation.<\/li><li>Newly designed buret tip ensures precise titration.<\/li><li>Non-corrosive PBT (polybutylene terephthalate) resin body.<\/li><li>Two RS-232C ports for balance and PC.<\/li><li>Free software for downloading titration results to a laptop or PC; includes the correct RS-232 cable.<\/li><\/ul>\n\n\n\n<p><strong>SPECIFICATION<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>ITEM<\/strong><strong><\/strong><\/td><td><strong>SPECIFICATIONS<\/strong><strong><\/strong><\/td><\/tr><tr><td>Titration method<\/td><td>Volumetric Karl Fischer reagent titration method<\/td><\/tr><tr><td>Titration control method<\/td><td>Intermittent addition of titrant while approaching the end point. (1) Control using a waiting interval timer of 1 &#8211; 99sec (INTERVAL). Titration stops when there is no change in the electrode potential during this interval. (2) Control by titration timer. (T-TIMER: 1 &#8211; 99min.)<\/td><\/tr><tr><td>End point detection<\/td><td>DC polarization potential difference detection<\/td><\/tr><tr><td>Buret capacity<\/td><td>10mL Reproducibility \u00b10.01 mL (for full discharge, standard deviation for n=5)<\/td><\/tr><tr><td>Liquid contact material<\/td><td>PTFE, ceramic and glass<\/td><\/tr><tr><td>Number of burets<\/td><td>1<\/td><\/tr><tr><td>Display screen<\/td><td>2 lines, 16 digit LCD with backlighting<\/td><\/tr><tr><td>Display units<\/td><td>mL (min. display is 0.001mL), mg H2O, %, or ppm<\/td><\/tr><tr><td>Measuring range<\/td><td>100 ppm &#8211; 100%<\/td><\/tr><tr><td>Minimum volume of titrant addition<\/td><td>0.005mL or 0.01mL<\/td><\/tr><tr><td>Calculation function<\/td><td>Concentration, factor standardization, statistics, recalculation<\/td><\/tr><tr><td>Titration cell capacity<\/td><td>150mL<\/td><\/tr><tr><td>Minimum volume of solvent<\/td><td>Approx. 30mL<\/td><\/tr><tr><td>External input\/output<\/td><td>Two RS-232C ports Port 1 (HOST) for PC connection. Port2 (BALANCE) for Balance connection.<\/td><\/tr><tr><td>Printers<\/td><td>Optional thermal and impact printer &#8211; please inquire<\/td><\/tr><tr><td>Power supply \/ Power consumption<\/td><td>AC100 &#8211; 240V, 50\/60 Hz, 100 VA<\/td><\/tr><tr><td>Dimensions<\/td><td>310 (W) x 270 (D) x 300 (H) mm<\/td><\/tr><tr><td>Weight<\/td><td>Approx. 6kg<\/td><\/tr><tr><td>Safety approval<\/td><td>CE approved<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>DESCRIPTION Features Small footprint with integrated magnetic stirrer. Function guide display allows simple operation. Newly designed buret tip ensures precise titration. Non-corrosive PBT (polybutylene terephthalate) resin body. Two RS-232C ports for balance and PC. Free software for downloading titration results to a laptop or PC; includes the correct RS-232 cable. SPECIFICATION ITEM SPECIFICATIONS Titration method Volumetric Karl Fischer reagent titration method Titration control method Intermittent&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-16082","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/16082","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=16082"}],"version-history":[{"count":1,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/16082\/revisions"}],"predecessor-version":[{"id":16085,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/16082\/revisions\/16085"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=16082"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}