{"id":16186,"date":"2020-12-03T14:13:27","date_gmt":"2020-12-03T07:13:27","guid":{"rendered":"http:\/\/attekno.com\/?page_id=16186"},"modified":"2020-12-03T14:13:31","modified_gmt":"2020-12-03T07:13:31","slug":"freeze-dryer-vd-800r","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/freeze-dryer-vd-800r\/","title":{"rendered":"Freeze dryer\u00a0VD-800R"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"128\" height=\"192\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2020\/12\/image.png\" alt=\"\" class=\"wp-image-16187\"\/><\/figure>\n\n\n\n<p>Ultimate vacuum range display function<\/p>\n\n\n\n<p>Displays Atmospheric pressure range\/Vacuum drying range\/Lyophilization range in order with LED when decompression is started&nbsp;to notify the progress of decompression. When pump is changed, the&nbsp;setting can be changed according to the pump capacity.<\/p>\n\n\n\n<p>The transparent door to see the trap&nbsp;status. Functional horizontal trap.<\/p>\n\n\n\n<p>As the cold trap installed horizontal in the&nbsp;body, easy to remove trapped ice and clean it&nbsp;easily. Besides, as the door of trapping room is&nbsp;transparent, the inside can be always observed.<\/p>\n\n\n\n<p>Output for recorder of vacuum degree.&nbsp;Nitrogen purge leak combined use&nbsp;nozzle.<\/p>\n\n\n\n<p>VD-550R\/800R are equipped with output&nbsp;terminals for recorder of vacuum degree. Plus, all&nbsp;three models equipped with leak port on the side&nbsp;of body and enables nitrogen purge from here.<\/p>\n\n\n\n<p>Multiple tubes, Chambers etc. available&nbsp;as an option.<\/p>\n\n\n\n<p>Abundant Options for freeze drying of variety of&nbsp;vessels. The power supply for chamber heater can&nbsp;be taken from the service outlet in VD main unit.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Specifications<\/td><td>&nbsp;<\/td><\/tr><tr><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td><strong>Model<\/strong><strong><\/strong><\/td><td><strong>VD-800R<\/strong><strong><\/strong><\/td><\/tr><tr><td><strong>Cooling temperature<\/strong><strong><\/strong><\/td><td><strong>-75<\/strong><strong>\u2103<\/strong><strong>&nbsp;(at no load) (*)<\/strong><strong><\/strong><\/td><\/tr><tr><td><strong>Trapping volume<\/strong><strong><\/strong><\/td><td><strong>Approx. 2000mL\/time<\/strong><strong><\/strong><\/td><\/tr><tr><td><strong>Volume inside chamber<\/strong><strong><\/strong><\/td><td><strong>Approx. 11.7L (Inner dia. 210 x 345mm)<\/strong><strong><\/strong><\/td><\/tr><tr><td>Vacuum gauge<\/td><td>Pirani gauge<\/td><\/tr><tr><td>Compressor<\/td><td>2 x 400W (Cascade refrigerating system)<\/td><\/tr><tr><td>Recommended vacuum pump<\/td><td>Oil-sealed Rotary Vacuum pump (Ultimate pressure below 50Pa, Displacement above 100L\/min )<\/td><\/tr><tr><td>Vacuum hose connection port<\/td><td>Outer dia. \u03c622mm (Rc 3\/8 Thread on inner surface, Convertible to different dia. )<\/td><\/tr><tr><td>Vacuum release<\/td><td>Leakage port with filter on the side of body (N2 Gas purge combined use, Hose attachment port, Pisco \u03c66mm), automatically released by halting vacuum pump.<\/td><\/tr><tr><td>Other functions<\/td><td>Hot gas defrosting (thawing in approx. 30 minutes, outlet for vacuum pump interlocking (Max. 3 sockets, 9A, with operation switch), outlet for chamber interlocking (up to 2 sockets, 3A) Ultimate pressure display function, Recorder output for degree of vacuum pressure (0 to 5V)<\/td><\/tr><tr><td>Dimensions\/Weight<\/td><td>490(W) x 600(D) x 805(H)mm, Approx. 97kg<\/td><\/tr><tr><td>Power supply<\/td><td>AC100V\/13A (Main unit only)<\/td><\/tr><tr><td>AC100V\/30A (at Max. use of outlet for interlocking)<\/td><\/tr><tr><td>Standard accessories<\/td><td>1 x Power plug (30A), 1 x Table mat<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Ultimate vacuum range display function Displays Atmospheric pressure range\/Vacuum drying range\/Lyophilization range in order with LED when decompression is started&nbsp;to notify the progress of decompression. When pump is changed, the&nbsp;setting can be changed according to the pump capacity. The transparent door to see the trap&nbsp;status. Functional horizontal trap. As the cold trap installed horizontal in the&nbsp;body, easy to remove trapped ice and clean it&nbsp;easily. Besides,&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-16186","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/16186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=16186"}],"version-history":[{"count":1,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/16186\/revisions"}],"predecessor-version":[{"id":16189,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/16186\/revisions\/16189"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=16186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}