{"id":18361,"date":"2023-01-25T14:48:26","date_gmt":"2023-01-25T07:48:26","guid":{"rendered":"https:\/\/attekno.com\/?page_id=18361"},"modified":"2024-07-02T01:21:39","modified_gmt":"2024-07-01T18:21:39","slug":"ultrasonic-homogenizer-vp-300n","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/ultrasonic-homogenizer-vp-300n\/","title":{"rendered":"Ultrasonic homogenizer VP-300N"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Easy operation. High output is suitable for large volume samples. Used with the stand. Various options such as the Cup horn makes it possible for Noncontact sonication.<\/h4>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/e-taitec.com\/wp-content\/uploads\/2017\/03\/VP-300N_VP-ST30.jpg\" alt=\"Ultrasonic homogenizer\"\/><figcaption class=\"wp-element-caption\">Ultrasonic homogenizer<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/e-taitec.com\/wp-content\/uploads\/2017\/01\/VP300_P87_ZU.jpg\" alt=\"\"\/><figcaption class=\"wp-element-caption\">Crushing of E. Coli<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Applications<\/h3>\n\n\n\n<p>\u2022Disruption and Solubilization of E. coli where protein is expressed<br>\u2022Random fragmentation of Genomic DNA, Emulsification of samples<br>\u2022Non-contact sonication with the Cup horn (Optional)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Features<\/h3>\n\n\n\n<h5 class=\"wp-block-heading\">Oscillation and Operation mode<\/h5>\n\n\n\n<p>Optimal oscillation is done by setting the chip used on the screen. PWM operation mode automatically adjusts the output according to the viscosity change of the sample.<br>POW operation mode performs stable oscillation when the sample viscosity and temp.<br>SEN operation modecontrols the output so that the value of oscillation sensor inside constantly (Effective for Sonicating for a long time with optional continuous<br>disruption cell)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Specifications<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Model<\/th><th>VP-300N (set of standard horn)<\/th><\/tr><\/thead><tbody><tr><td>High frequency output<\/td><td>Maximum 300 W<\/td><\/tr><tr><td>Transducer normal output<\/td><td>50 to 200 W (*)<\/td><\/tr><tr><td>Oscillation frequency range<\/td><td>19 to 21 Hz<\/td><\/tr><tr><td>Tuning<\/td><td>Automatically<\/td><\/tr><tr><td>Operation mode<\/td><td>PWM operation:<br>Automatic output adjustment according to viscosity change of sample<br>POW operation:<br>Stable oscillation when change in viscosity or temp are small<br>SEN operation:<br>Controls the output so the value of oscillation sensor inside is constant<\/td><\/tr><tr><td>Other functions<\/td><td>Timer operation (1 sec to 120 min)<br>Programmed interval operation (ON: 3 to 60 sec, OFF: 1 to 60 sec)<\/td><\/tr><tr><td>Display<\/td><td>Real time output value %, Output value setting %, Oscillation<br>frequency, The tip used, Operation mode<\/td><\/tr><tr><td>Configuration<\/td><td>Main unit, Converter, \u03c612 mm Standard horn (Pre-installed Tip)<\/td><\/tr><tr><td>Oscillation switch<\/td><td>Equipped in Main unit (Optional foot switch can be used)<\/td><\/tr><tr><td>Dimensions\/Weight<\/td><td>143(W) x 360(D) x 283(H) mm, Approx. 6.7 kg<\/td><\/tr><tr><td>Standard accessories<\/td><td>Standard horn (\u03c612 mm: VP-HN12), Tip (\u03c612 mm: VP-ET12)<\/td><\/tr><tr><td>Power supply<\/td><td>AC 100 V\/5 A<\/td><\/tr><tr><td>\u25cfThe upper limit varies depending on the horn and the tip used.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Dimensions<\/h3>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/e-taitec.com\/wp-content\/uploads\/2017\/01\/VP-300N-1.jpg\" alt=\"\"\/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Easy operation. High output is suitable for large volume samples. Used with the stand. Various options such as the Cup horn makes it possible for Noncontact sonication. Applications \u2022Disruption and Solubilization of E. coli where protein is expressed\u2022Random fragmentation of Genomic DNA, Emulsification of samples\u2022Non-contact sonication with the Cup horn (Optional) Features Oscillation and Operation mode Optimal oscillation is done by setting the chip used&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-18361","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/18361","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=18361"}],"version-history":[{"count":2,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/18361\/revisions"}],"predecessor-version":[{"id":19143,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/18361\/revisions\/19143"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=18361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}