{"id":18364,"date":"2023-01-25T14:49:52","date_gmt":"2023-01-25T07:49:52","guid":{"rendered":"https:\/\/attekno.com\/?page_id=18364"},"modified":"2023-01-25T14:49:54","modified_gmt":"2023-01-25T07:49:54","slug":"ultrasonic-homogenizer-vp-050n","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/ultrasonic-homogenizer-vp-050n\/","title":{"rendered":"Ultrasonic homogenizer VP-050N"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Automatic tuning and easy operation. Various operation modes according to the condition of samples. Small hand-held type is suitable for small-volume samples. For disruption of E. coli, etc. after expression of protein<\/h4>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/e-taitec.com\/wp-content\/uploads\/2017\/01\/VP-050N.jpg\" alt=\"\"\/><figcaption class=\"wp-element-caption\">Image of using step-type micro tip (option)<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/e-taitec.com\/wp-content\/uploads\/2017\/03\/VP050-zu1-en.jpg\" alt=\"\"\/><figcaption class=\"wp-element-caption\">Random fragmentation of DNA (from left after 0, 1, 1.5, 2, 4, 8, 16 min of processing time for each)<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Applications<\/h3>\n\n\n\n<p>\u2022Disruption and Solubilization of E. coli where protein is expressed<br>\u2022Random fragmentation of Genomic DNA<br>\u2022Homogenization and Emulsification of samples<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Features<\/h3>\n\n\n\n<h5 class=\"wp-block-heading\">Automatic tuning and Operation mode<\/h5>\n\n\n\n<p>The automatic tuning before use is completed in about 5 seconds just by pressing the button. Possible for Timer operation and Program interval operation.<br>Equipped with PWM operation mode that automatically adjusts the output according to the viscosity change of the sample. It is also equipped with POW operation mode that performs stable oscillation when the sample viscosity and temp. changes are small.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Specifications<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Model<\/th><th>VP-050N<\/th><\/tr><\/thead><tbody><tr><td>High frequency output<\/td><td>Maximum 50 W<\/td><\/tr><tr><td>Transducer normal<\/td><td>output 10 to 40 W<\/td><\/tr><tr><td>Oscillation frequency<\/td><td>range 19.5 to 20.5 Hz<\/td><\/tr><tr><td>Turning<\/td><td>Automatically<\/td><\/tr><tr><td>Operation mode<\/td><td>PWM operation: Automatic output adjustment according to viscosity change of sample<br>POW operation: Stable oscillation when change in viscosity or temp are small<\/td><\/tr><tr><td>Other functions<\/td><td>Timer operation (1 sec to 120 min)<br>Programmed interval operation (ON: 3 to 60 sec, OFF: 1 to 60 sec)<\/td><\/tr><tr><td>Display<\/td><td>Real time output value %, Output value setting %,<br>Output value when oscillation start (%), Oscillation frequency<\/td><\/tr><tr><td>Configuration<\/td><td>Main unit, Converter (Horn\/Oscillation switch integrated)<\/td><\/tr><tr><td>Oscillation switch<\/td><td>Equipped in both Main unit and Converter (Optional foot switch can be used)<\/td><\/tr><tr><td>Dimensions<\/td><td>122 x 288 x 283 mm<\/td><\/tr><tr><td>Weight<\/td><td>Approx. 4.5 kg<\/td><\/tr><tr><td>Power supply<\/td><td>AC100 to 240 V\/1 A<\/td><\/tr><tr><td>\u2022 Optional step type Micro Tip required for use.<\/td><\/tr><tr><td>\u2022 The chips for the previous model VP-5S cannot be used.<\/td><\/tr><tr><td>\u2022 The chips for this model can used in the previous model VP-5S.<\/td><\/tr><tr><td>\u2022 The chips for the previous model VP-5 cannot be used.<\/td><\/tr><tr><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Dimensions<\/h3>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/e-taitec.com\/wp-content\/uploads\/2017\/01\/VP-050N.png\" alt=\"\"\/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Automatic tuning and easy operation. Various operation modes according to the condition of samples. Small hand-held type is suitable for small-volume samples. For disruption of E. coli, etc. after expression of protein Applications \u2022Disruption and Solubilization of E. coli where protein is expressed\u2022Random fragmentation of Genomic DNA\u2022Homogenization and Emulsification of samples Features Automatic tuning and Operation mode The automatic tuning before use is completed in&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-18364","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/18364","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=18364"}],"version-history":[{"count":1,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/18364\/revisions"}],"predecessor-version":[{"id":18365,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/18364\/revisions\/18365"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=18364"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}