{"id":20239,"date":"2026-05-30T16:09:59","date_gmt":"2026-05-30T09:09:59","guid":{"rendered":"https:\/\/attekno.com\/?page_id=20239"},"modified":"2026-05-30T16:13:11","modified_gmt":"2026-05-30T09:13:11","slug":"lp980-transient-absorption-edinburgh-instruments","status":"publish","type":"page","link":"https:\/\/attekno.com\/index.php\/lp980-transient-absorption-edinburgh-instruments\/","title":{"rendered":"LP980 Transient Absorption &#8211; EDINBURGH INSTRUMENTS"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"20239\" class=\"elementor elementor-20239\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-09a193c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"09a193c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2279ef6\" data-id=\"2279ef6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-dc448be elementor-widget elementor-widget-elementskit-heading\" data-id=\"dc448be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"elementskit-heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"ekit-wid-con\" ><div class=\"ekit-heading elementskit-section-title-wraper text_left   ekit_heading_tablet-   ekit_heading_mobile-\"><h2 class=\"ekit-heading--title elementskit-section-title \">LP980 Transient Absorption<\/h2><div class=\"ekit_heading_separetor_wraper ekit_heading_elementskit-border-divider ekit-dotted\"><div class=\"elementskit-border-divider ekit-dotted\"><\/div><\/div><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-151979f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"151979f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-716da82\" data-id=\"716da82\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1c8783a ekit-equal-height-disable elementor-widget elementor-widget-elementskit-image-box\" data-id=\"1c8783a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"elementskit-image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"ekit-wid-con\" >\n            <div class=\"elementskit-info-image-box ekit-image-box text-center simple-card\" >\n\n                \n                <div class=\"elementskit-box-header image-box-img-center\">\n\n                    <img fetchpriority=\"high\" decoding=\"async\" width=\"2560\" height=\"998\" src=\"https:\/\/attekno.com\/wp-content\/uploads\/2026\/04\/LP980-Transient-Absorption-Edinburgh-scaled.webp\" class=\"attachment-full size-full wp-image-19932\" alt=\"LP980 Transient Absorption\" srcset=\"https:\/\/attekno.com\/wp-content\/uploads\/2026\/04\/LP980-Transient-Absorption-Edinburgh-scaled.webp 2560w, https:\/\/attekno.com\/wp-content\/uploads\/2026\/04\/LP980-Transient-Absorption-Edinburgh-300x117.webp 300w, https:\/\/attekno.com\/wp-content\/uploads\/2026\/04\/LP980-Transient-Absorption-Edinburgh-1024x399.webp 1024w, https:\/\/attekno.com\/wp-content\/uploads\/2026\/04\/LP980-Transient-Absorption-Edinburgh-768x299.webp 768w, https:\/\/attekno.com\/wp-content\/uploads\/2026\/04\/LP980-Transient-Absorption-Edinburgh-1536x599.webp 1536w, https:\/\/attekno.com\/wp-content\/uploads\/2026\/04\/LP980-Transient-Absorption-Edinburgh-2048x798.webp 2048w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/>\n                <\/div>\n                \n                <div class=\"elementskit-box-body ekit-image-box-body\">\n                    <div class=\"elementskit-box-content ekit-image-box-body-inner\">\n                                                <h3 class=\"elementskit-info-box-title\">\n\n                        LP980 Transient Absorption\n                        \n                    <\/h3>\n                                                            <div class=\"elementskit-box-style-content\">\n                        The LP980 Transient Absorption Spectrometer sets the benchmark in transient absorption research, becoming the go-to instrument for a wide array of photochemical, physical, and biological applications.\n\nAs the first of its kind on the market, the LP980 enables precise measurement of transient absorption (TA), laser-induced fluorescence (LIF), and phosphorescence up to 2.55 \u00b5m, with time scales ranging from nanoseconds to seconds. Its dual monochromator\/spectrograph design allows for both spectral and kinetic acquisitions in one device, saving you both time and cost.\n\nAvailable in two models\u2014LP980-K (kinetic PMT detector) and LP980-KS (kinetic PMT and spectral ICCD detector)\u2014the LP980 can be customised with various pump lasers, probe sources, sample holders, and detectors to perfectly match your research needs. Our technical sales team is ready to help you configure the ideal setup for your experiments.\n\nWith the intuitive L900\u00ae software package, data acquisition is straightforward, and comprehensive analysis tools like \u0394OD calculations and multi-component decay fitting are included, eliminating the need for additional software.\n\n                    <\/div>\n                                    <\/div>\n\n                            <\/div>\n            <\/div>\n    <\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e5ceb50 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e5ceb50\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-979b846\" data-id=\"979b846\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e8e2e1d elementor-widget elementor-widget-text-editor\" data-id=\"e8e2e1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table width=\"608\"><tbody><tr><td width=\"265\">LP980 Base Configuration<\/td><td width=\"343\">Specification<\/td><\/tr><tr><td width=\"265\">Monochromator<\/td><td width=\"343\">Czerny-Turner with triple grating turret, 325 mm focal length, 25 \u00b5m to 10 mm computer-controlled (continuously adjustable) motorised slits<\/td><\/tr><tr><td width=\"265\">Laser Excitation Source<\/td><td width=\"343\">Flashlamp pumped Q-switched Nd:Yag laser operating at 1064 nm, 532 nm, 355 nm or 266 nm. OPO, tuneable in the range 410 nm &#8211; 710 nm (signal). Idler and UV doubler options possible<\/td><\/tr><tr><td width=\"265\">Sample Geometry<\/td><td width=\"343\">Transverse sample excitation geometry included as standard<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>LP980 Transient Absorption LP980 Transient Absorption The LP980 Transient Absorption Spectrometer sets the benchmark in transient absorption research, becoming the go-to instrument for a wide array of photochemical, physical, and biological applications. As the first of its kind on the market, the LP980 enables precise measurement of transient absorption (TA), laser-induced fluorescence (LIF), and phosphorescence up to 2.55 \u00b5m, with time scales ranging from nanoseconds&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-20239","page","type-page","status-publish","hentry","clearfix"],"_links":{"self":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/20239","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/comments?post=20239"}],"version-history":[{"count":4,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/20239\/revisions"}],"predecessor-version":[{"id":20244,"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/pages\/20239\/revisions\/20244"}],"wp:attachment":[{"href":"https:\/\/attekno.com\/index.php\/wp-json\/wp\/v2\/media?parent=20239"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}