[cmsmasters_row data_padding_bottom=”50″ data_padding_top=”0″ data_bg_color=”#ffffff” data_color=”default” data_bot_style=”default” data_top_style=”default” data_width=”boxed” data_shortcode_id=”dm6k7l70h”][cmsmasters_column data_width=”1/1″ data_shortcode_id=”00grd43b9g” data_border_style=”default” data_animation_delay=”0″][cmsmasters_text shortcode_id=”l17y1yfzey” animation_delay=”0″]

[/cmsmasters_text][/cmsmasters_column][/cmsmasters_row][cmsmasters_row data_padding_bottom=”50″ data_padding_top=”0″ data_bg_color=”#ffffff” data_color=”default” data_bot_style=”default” data_top_style=”default” data_width=”boxed” data_shortcode_id=”2rq4exyob”][cmsmasters_column data_width=”1/1″ data_bg_position=”top center” data_bg_repeat=”no-repeat” data_bg_attachment=”scroll” data_bg_size=”cover” data_border_style=”default” data_animation_delay=”0″ data_shortcode_id=”lvkh7tz5sh”][cmsmasters_tabs shortcode_id=”vuceyuydvs” mode=”tab” active=”1″ animation_delay=”0″][cmsmasters_tab shortcode_id=”91c5fa5mf” title=”Features”]

ENVAIR units have certificates. The microbiological safety cabinets are designed and constructed to fulfil the requirements of the European standard EN 12469:2000 and have TÜV certificates. The ENVAIR microbiological safety workbenches are worldwide adopted for product, personnel and environment protection. The cabinets are especially suitable for handling dangerous materials which may be potentially harmful to humans and/or animals.

Features: ENVAIR eco safe Comfort Plus

  • Energy save blowers
  • LED light technology
  • Energy consumption <84,4 W
  • Low noise level <42,5 dB(A)
  • Low CO2-emission
  • Motorized hinged front visor for optimal cleaning
  • Side walls made of safety glass
  • Stainless steel work area
  • Multi piece stainless steel work tray
  • Multi-function display with PLC control
  • Ergonomic design

Standard equipment

  • Motorized hinged front visor for optimal cleaning
  • 1x vacuum tap
  • 1x gas tap with safety solenoid valve for automatic shut-off
  • 1 or 2 electric sockets, depending on model

Main applications

  • Microbiology
  • Virology
  • Haematology
  • Cell cultures
  • Genetics

Operation principle

  • 70 % recirculating air via main HEPA Filter H14
  • 30 % via exhaust HEPA Filter H14

Most economic and most silent safety workbench worldwide

Test winner 2012 of ETH Zürich

Video

[/cmsmasters_tab][cmsmasters_tab shortcode_id=”7uzzjcblj” title=”Models”]

 

Model Type ENVAIR eco safe Plus 0.9m ENVAIR eco safe Plus 1.2m ENVAIR eco safe Plus 1.8m
Standards EN 1822, EN12469, EN61010-1, ISO 14644.1 EN 1822, EN12469, EN61010-1, ISO 14644.1 EN 1822, EN12469, EN61010-1, ISO 14644.1
Outer dimensions 1045 x 2345 x 855 1350 x 2345 x 855 1960 x 2345 x 855
Inner dimensions 887 x 740 x 580 1192 x 740 x 580 1802x 740 x 580
Inflow 0.45 (m/s) 0.45 (m/s) 0.45 (m/s)
Downflow 0.35 (m/s) 0.35 (m/s) 0.35 (m/s)
Electr. connected values 220-240V,AC, 50Hz,1ø 220-240V,AC, 50Hz,1ø 220-240V,AC, 50Hz,1ø

[/cmsmasters_tab][cmsmasters_tab shortcode_id=”wqgevmspqb” title=”Accessories”]

Support stands

Support stand with castor wheels

  • Two standard heights available: 750mm or 900mm
  • Durable polyurethane wheels with 360° rotation
  • Break system at the front wheels

Support stand with adjustable feet

  • Two standard heights available: 750mm or 900mm

Cabinet accessories

Electric socket and media connections

  • Electric sockets, Europe / Worldwide
  • Media connections (Compressed air, Gas, Vacuum, etc.)
  • Europe / Worldwide model DIN 12898, DIN 12919, DIN 3537

IV suspension bar with hooks
An attached IV suspension bar offers on pharmaceutical applications an easy possibility to hang or store IV bags during the work course. Besides it increases the effectiveness in the work area.

  • Stainless steel IV bar with 6 hooks

UV Lamp

  • Controlled by an automatic UV-timer via the microprocessor supported control panel.
  • Radiation of 253.7 Nm allows high-efficient decontamination
  • The lamp is mounted outside the view line of the user for good and safe radiation of the inner surfaces of the work zone.

Attention: Please observe the safety measures for your personnel when using the UV lamp. A UV lamp is not a substitution for good and effective cleaning and the effective lifetime is limited normally to 12 months, depending on the total number of operation hours. Replace the UV lamp every 12 months.

Ergonomic foot rest

  • Inclined, supports a good posture
  • Adjustable height
  • Anti-slide coating, chemical resistance

Ergonomic laboratory chair

  • Laboratory-suitable construction
  • Corresponds to cleanroom class 100
  • Alcohol-resistant PVC material
  • Adjustable height 395-490 mm

[/cmsmasters_tab][cmsmasters_tab shortcode_id=”v99iis59b5″ title=”Airflow”]

 

[/cmsmasters_tab][cmsmasters_tab shortcode_id=”rmnh4urbq” title=”Gallery”]

ENVAIR eco safe Comfort Plus

Multi-function display

Pre-filter for Safety Workbench