Addressed high temperature with excellent durability. There is a type with possible powerful external circulation.
![Unit water bath](https://e-taitec.com/wp-content/uploads/2017/04/SP-12N_2.jpg)
![](https://e-taitec.com/wp-content/uploads/2017/01/SP-12N.jpg)
Applications
●Various incubation such as enzyme reaction at high temperature
●Inactivation of serum and thermal insulation of culture medium, incubation of thermophile
●Circulation into spectrophotometer
Features
Available to use at +100 ºC and external circulating
![](https://e-taitec.com/wp-content/uploads/2017/01/SP-12R_Jyunkanbu.jpg)
Durable enough for high temperature operation by double cooling fans which is away from the influence of strong heater and steam. Circulation flow is adjustable up to 6.2L/min and also adjustable mixing in bath.
Addressed to use at below room temperature
Temperature setting range is -20ºC – +100 ºC for SP-12N. Combining with optional cooling system enables to use at below room temperature.
SP-12N has simple OFF timer and buzzer timer
SP-12N has simple OFF timer and buzzer timer.
A lot of options other than attached plastic water bath
It is possible to facile immediate use with attached poly C water bath or optimization with options for container and purpose.
Specifications
Model | SP-12N |
---|---|
Temperature Range | RT+5ºC – +100 ºC (*) |
Temp. Control Accuracy | from ±0.1ºC |
Minimum temperature setting unit | 0.1ºC (setting and display) |
Outside circulation function | Max. flow : 6.2L/min |
Temperature setting | By UP/ DOWN key |
Flow | Jet blast (volume adjust) |
Temperature Display | Digital display (switching between setting temperature and inside chamber temperature) |
Timer | Buzzer timer : 1min – 99h59min OFF timer : 1min – 99h59min |
Heater | 1.2kW (time proportioning variable output : 0-100%) |
Weight | Approx. 5kg |
Water level range | Minimum water level: 55mm (from the bottom of PolyC water bath) |
Safety device / function | Circuit protector (15A), fuse (2A), float type prohibition of boiling while empty, protective cover for heater Misalignment high and low temperature error, lowing water, sensor error, auto tuning error, non-volatile storage error ※Notified by buzzer |
Occupying dimensions inside bath | 130 x 85 x 145Hmm |
Dimensions | 130 x 164 x 315Hmm |
Power Supply | AC100V 13A |
Standard Accessory | PolyC water bath x 1 (can be use at up to +70 ºC), micro tube floater x 1 |
(*)Temperature setting range is -20ºC – +100 ºC for SP-12N. Combining with optional low temperature water bath unit or immersion cooler enables control below room temperature. When using at over +70 ºC, using optional silicon oil, stainless thermal insulation water bath and cover for stainless thermal insulation water bath are required. |